Classification (see below) |
Actual Annual Emissions |
Potential Annual Emissions |
Permit Type |
|||
|
All Classes |
Criteria < 200 lbs |
N/A |
No Permit Required |
|||
|
All Classes |
N/A |
All Pollutants > de minimis |
Construction Permit (+ modeling if HAP) |
|||
|
A & B |
200 lbs < Criteria < 876 lbs |
NA |
Source Registration Permit |
|||
|
A & B |
Criteria > 876 lbs -OR- |
Criteria > 4380 lbs @ 0-500 ft from property line -or- Criteria > 7972 lbs @ 500+ ft from the property line |
Construction Permit |
|||
|
C & D |
200 lbs < Criteria < de minimis |
Criteria < de minimis |
Source Registration Permit |
|||
|
Incinerator/ Asphaltic Concrete |
N/A |
N/A |
Construction Permit |
|||
|
A & B |
Individual HAP < 200 lbs -AND- |
Individual HAP < 4380 lbs -or- Individual HAP < 112(g) whichever is more stringent |
No Permit Required |
|||
|
A & B |
Ind. HAP > 200 lbs -AND- |
Individual HAP < 4380 lbs -or- Individual HAP < 112(g) whichever is more stringent |
Source Registration |
|||
|
A & B |
N/A |
Individual HAP > 4380 lbs -or- Individual HAP > 112(g) whichever is more stringent |
Construction Permit [& modeling if greater than 112(g)] |
|||
|
C & D |
Ind. HAP < 200 lbs -AND- |
Individual HAP < 4380 lbs -or- Individual HAP < 112(g) whichever is more stringent |
No Permit Required |
|||
|
C & D |
Ind. HAP > 200 lbs -AND- |
4380 lbs < Ind. HAP < 10 tons -or- 112 (g) < Ind. HAP < 10 tons whichever is more stringent |
Source Registration Permit [& modeling if greater than 112(g)] |
|||
Class A: PTE > major source levels
Class B: de minimis < PTE < major source levels
Class C: 10 tons < PTE < de minimis
Class D: PTE < 10 tons
Potential Annual Emissions (PTE) is the emission rate of any pollutant at maximum design capacity. Federally enforceable limits, inherent system controls, and process bottlenecks can be taken into account; add-on control devices cannot.